Fire Alarm
-
CP 3500 LOM P
Call for Price Fire AlarmLOOP MODULE FOR FIRE CONTROL PANEL DC3500, PROTECTED Microprocessor-controlled loop interface for dc3500 with special coating against condensing water for uninterruptible and short-circuit-proof use with 126 Loop 3000 fire detection system components.
Highlights
- Connection of Loop 3000 components in loop structure or spur-structure
- 2-wire-system loop with up to 3.500 m loop length
- Easy and flexible installation and initialization via automatic and manual addressing
- System plug to connect to dc3500 system
- System socket to connect additional modules to the dc3500 system
-
CS 200 R
Call for Price Fire AlarmSOUNDER – RED 112 DB
Acoustic multiple-tone sounder for an external acoustic alarm according to EN 54-3
Highlights
- 32 different tones via DIP-switch, including DIN-tone
- Automatic synchronization
- Integrated two-tone alarm function
- Flat design
- Internal volume adjustment
-
CT 3000 OT
Call for Price Fire AlarmMULTI-SENSOR DETECTOR, CONVENTIONAL
Optical and thermal multi-sensor detector for conventional systems for earliest fire detection and indication in all environments with difficult ambient conditions according to EN 54-7 and EN 54-5 class A1
Highlights
- Integrated temperature measurement as the rate of the rising procedure and maximum value by EN 54-5
- Professional smoke detection system with the highest reliability for secure alarm verification with three-fold measurement
- Periodic sensor test
- Alarm output to control parallel indicator
- LED for alarm (red)
- Integrated locking system for protection against removal and tampering
- Delivery including protective cover for the installation phase
-
CT 3000 PBDH ABSR
Call for Price Conventional SystemsMANUAL CALL POINT, RED
Manual Call Point for conventional systems for the manual activation of an alarm and status display via LED according to EN 54-11
Highlights
- Push Button mechanics for the activation of a manual alarm
- Integrated reset mechanics (operation from inside)
- LED for alarm (red)
- Encapsulated plastic housing
-
CT 3000 T
Call for Price Fire AlarmTHERMAL DETETOR, CONVENTIONAL
Heat detector with fixed and rate of rising temperature settings for conventional systems for earliest fire detection and indication in all environments with difficult ambient conditions according to EN 54-5 class A1.
Highlights
- Integrated temperature measurement as the rate of the rising procedure and maximum value by EN 54-5
- Periodic sensor test
- Alarm output to control parallel indicator
- LED for alarm (red)
- Integrated locking system for protection against removal and tampering
- Delivery including protective cover for the installation phase
-
DC 3004PLUS
Call for Price Fire AlarmFIRE CONTROL PANEL DC 3004PLUS, M-TYPE HOUSING, GB
Microprocessor-controlled fire control panel for use with the loop 3000 fire detection system components.
Highlights
- Large LCD, 160 x 80 points
- RS-232 interface for easy programming via DPT-Software
- Space for 2 modules to connect 2 x 126 loop 3000 fire detection system components per module
- Up to 128 programmable detector zones
- Event log memory of up to 500 messages
- Easy programming of up to 504 connections
- In accordance with EN 61000-6-3 class B for emissions, so suitable for use in sensitive areas
- Option for 2 conventional interface cards for controlling up to 16 conventional zones
- Extinguishing interface for controlling extinguishing and gas suppression systems in accordance with EN 12094
- Integrated interface for the connection of up to 63 additional network components
- Integrated control of extinguishing systems via the standard extinguishing interface in accordance with VdS
-
DC3500M
Call for Price Fire AlarmFIRE CONTROL PANEL DC3500 M
Compact microprocessor-controlled fire control panel for use with the Loop 3000 fire detection system components.
Highlights
- Clear display and easy operation via the color display with touchscreen
- USB-Interface for easy programming via DPT-Software
- Space for up to 15 modules to connect up to 126 Loop 3000 fire detection system components per module
- Programming of up to 1890 detector zones
- Event log memory for 100.000 messages
- Easy programming of up to 10.000 cause & effects
-
DCC4
Call for Price Fire AlarmFIRE CONTROL PANEL 4 ZONES, GB
Compact microprocessor-controlled fire control panel for use with the CT 3000 fire detection system components. Approved according to EN 54-2: 1997/A1: 2006 and EN 54-4: 1997/A2: 2006
Highlights
- Clear display and easy operation with LED displays and operation keys
- Connection possibility for 4 conventional zones for the use with the CT 3000 fire detection components with up to 20 detectors per zone
- An integrated power supply according to EN 54-4: 1997/A2: 2006 with 1 output for external devices rated at 24 V DC
- Independent connection of detector and signaling device zones
- Integrated “one-man-revision mode”
- Manual control of signaling devices via separate input
-
DCC8
Call for Price Security SystemsFIRE CONTROL PANEL 8 ZONES, GB
Compact microprocessor-controlled fire control panel for use with the CT 3000 fire detection system components. Approved according to EN 54-2: 1997/A1: 2006 and EN 54-4: 1997/A2: 2006
Highlights
- Clear display and easy operation with LED displays and operation keys
- Connection possibility for 8 conventional zones for the use with the CT 3000 fire detection components with up to 20 detectors per zone
- Extension option via 4 zone modules for up to 16 conventional zones for CT 3000 fire detection components
- An integrated power supply according to EN 54-4:A2 2006
- Independent connection of detector and signaling device zones
- Integrated “one-man-revision mode”
- Manual control of signaling devices via separate input
- Programming options such as alarm delay
- Panel network of max. two fire control panels
-
DLI 3240 PS X1
Call for Price Fire Alarm2 LOOP INTERFACE, ACTIVE, 2 X 140 MA FOR DETECT 3004PLUS
Microprocessor-controlled loop interface for dc3004plus for uninterruptible and short-circuit-proof use with 2 x 126 Loop 3000 fire detection system components.
Highlights
• Connection of Loop 3000 components in loop structure or spur-structure
• 2-wire-system loop with up to 3.500 m loop length.
• Easy and flexible installation and initialization via automatic and manual addressing
• Integrated RS-232 interface for easy analysis of the loop components, the preadjustment of functions, and commissioning of Loop 3000
• 8 integrated freely programmable open-collector-alarm outputs
• 2 integrated open-collector-alarm outputs for the programming of collecting functions
• Commissioning and service tool for analyzing and fault-finding functions with I-Check software -
DLI 3240 PS X1 1L
Call for Price Fire Alarm1 LOOP INTERFACE, ACTIVE, 140 MA FOR DETECT 3004PLUS
Microprocessor controlled loop interface for dc3004PLUS for the uninterruptible and short-circuit-proof use with 126 loop3000 fire detection system components.
Highlights
• Connection of Loop 3000 components in loop structure or spur-structure
• 2-wire-system loop with up to 3.500 m loop length.
• Easy and flexible installation and initialization via automatic and manual addressing
• Integrated RS-232 interface for easy analysis of the loop components, the preadjustment of functions, and commissioning of Loop 3000
• 8 integrated freely programmable open-collector-alarm outputs
• 2 integrated open-collector-alarm outputs for the programming of collecting functions
• Commissioning and service tool for analyzing and fault-finding functions with I-Check software -
DMCL05
Call for Price Fire AlarmCONVENTIONAL MANUAL CALL POINT resettable with a key without breaking glass led and alarm resistor integrated, RED color, EN54-11, CE according to CPD
Highlights
- CE certified according to CPD
- Conform with the norm EN54-11
- Key for reset
- The separate key for test
- No broken glass
- Red color for Alarm status
- Yellow color for extinguishing command
- Blue color for Extinguishing abort
-
DSF 2000-RR
Call for Price Fire AlarmCONVENTIONAL sounder + flash (red flash + red box);
3 different sounds, 97dB, low current consumption, IP21C, EN54-3, EN54-23, CE according to CPD/CPR (exist also in white flash), base included
Highlights
- Ceiling: up to 3m height – 8 m diameter
- Wall: up to 2,4 m height- 4,2m
- depth/width
- Flash Red color
- IP21C
- Ceiling or wall mounting
- 3 different sounds
- 97 dB Sound Power@1m
-
IOM 3311
Call for Price Fire AlarmIN-/OUTPUT MODULE 1X
Intelligent Input/Output module for the Loop 3000 with bidirectional isolator according to EN 54-18 and EN 54-17. With one monitored input and one potential free relay output
Highlights
- Connecting module with one programmable input and one programmable output
- Programming of different s different switching variants of input and output rol for one detector group.
- Monitoring of the operating status via Loop 3000
- Independent programming of input and output
- Automatic and manual addressing on Loop 3000
- Integrated isolator and T-branch option
- Functions completely integrated via Loop 3000-protocol
- Multicolour LED for alarm (red) and fault (yellow)
- A robust wall mounted housing according to IP 54
-
OC05
Call for Price Fire AlarmCONVENTIONAL OPTICAL SMOKE DETECTOR, 1 remote led output, EN54-7 , CE according to CPD/CPR
Highlights
- Photoelectric scattering (Tyndall effect)
- 1 remote alarm indicator output
- Lockable
- Standard EN54-7
- Cable section max 2,5mm²
- 12V version
-
OMS 3301
Call for Price Fire AlarmOUTPUT MODULE FOR SIGNALING DEVICES 1X
Intelligent Input/Output module for the Loop 3000 for the control of external optical and acoustic signaling devices with bidirectional isolator according to EN 54-17 and EN 54-18. Including one monitored fault input and one potential free relay output for signaling devices.
Highlights
- Integrated automatic switch function of the output at “external signal line on/off” signal by the fire control panel
- Connecting module with one freely programmable fault input and one output for the connection of signalling devices
- Programming of different switching variants of input and output also with time control
- Monitoring of the operating status via Loop 3000
- Independent programming of input and output
- Automatic and manual addressing on Loop 3000
- Integrated isolator and T-branch option
- Functions completely integrated via Loop 3000-protocol
- Multi-color LED for alarm (red) and fault (yellow)
- Robust wall-mounted housing according with IP 54
-
PL 3200 O
Call for Price Fire AlarmOPTICAL SMOKE DETECTOR WITHOUT ISOLATOR
Optical smoke detector for Loop 3000 with two optical sensors for earliest fire detection and indication according to EN 54-7
Highlights
- Pollution detection of the smoke measurement chamber by an additional optical path
- Detector sensitivities are automatically adapted and programmable
- Fault monitoring of the measurement chamber signal and Loop 3000 electronics
- Periodic sensor test
- Automatic and manual addressing with Loop 3000
- Alarm output to control parallel indicator
- Functions completely integrated via Loop 3000 protocol
- Presence and absence switching with selectable sensitivities
- Storage of last maintenance date
- Multicolour LED for alarm (red) and fault (yellow)
- Delivery including protective cover for the installation phase
-
PL 3300 MCP
Call for Price Fire AlarmMANUAL CALL POINT
Manual Call Point for loop3000 for the manual activation of an alarm with bidirectional isolator according to EN 54-11: A1, EN 54-17. Red plastic housing with imprint “burning house”.
Highlights
- Manual Call Point mechanics for the activation of a manual alarm
- Non-destructive activation and reset via mechanics
- Automatic and manual addressing with Loop 3000
- Integrated Isolator with T-branch
- Functions completely integrated via Loop 3000-protocol
- Integrated red Alarm-LED
-
PL 3300 OTi
Call for Price Fire AlarmINTELLIGENT MULTI-SENSOR DETECTOR WITH ISOLATOR
Intelligent optical and thermal multi-sensor detector for loop3000 with two optical and two thermal sensors and a bidirectional isolator for earliest fire detection and indication in all environments with difficult ambient conditions, according to EN 54-5/-7 /-17, prEN 54-29 and CEA 4021. Fusion® technology for the detection of the smallest smoke particles and fires in the early stage by using the wavelengths of the wide-band white light spectrum.
Highlights
- Individual use of the thermal measurement according to EN 54-5 in the sensitivity levels 2 to 5 as maximum detector (static –> A1S, A2S) or as rate-of-rise detector with a maximum threshold (differential and static –> A1R, A2R)
- Individual change of detector class for sensitivity levels 2 to 5 using Easy Check 3000
- Pollution detection of the smoke measurement chamber by an additional optical path
- Detector sensitivities are automatically adapted and programmable
- Integrated measurement system and algorithm for condensation recognition (Humitec®)
- Intelligent analysis and suppression mode for the elimination of false alarms (e.g. cigarette smoke)
- Highest reliability by optimal adjustment of the alarm threshold via intelligent algorithm for the fire detection
- Fault monitoring of the measurement chamber signal and Loop 3000 electronics
- Periodic sensor test
- Automatic and manual addressing on Loop 3000
- Integrated isolator and T-branch option
- Alarm output to control parallel indicator
- Functions completely integrated via Loop 3000 protocol
- Presence and absence switching with selectable sensitivities
- Storage of last maintenance date
- Multicolour LED for alarm (red) and fault (yellow)
- Delivery including dust protection cover for installation phases
-
PL 3300 PBDH ABS R
Call for Price Security SystemsMANUAL CALL POINT, RED
Manual Call Point for Loop 3000 for the manual activation of an alarm with bidirectional Isolator and status display via LED according to EN 54-11.
Highlights
- Push Button mechanics for the activation of a manual alarm
- Activation after smash of the front glass
- Integrated reset mechanics
- Automatic and manual addressing with Loop 3000
- Integrated Isolator and T-branch option
- Functions completely integrated via Loop 3000-protocol
- Integrated red LED for Alarm